Hakuna Matatted --- 15 years ago -

Does an a/c unit in the shade work better than an a/c in full sun? I'm considering putting up a shade structure for the a/c if it will help it work eaiser.

Any input?

Before me moved into the house, there was a huge tree shading the whole backyard including the roof and a/c unit. The tree had to be taking out due to it's proximity to the house and now the back yard and whole west side of the house is exposed. I'm trying to find anything that will help it cool down easier. It's just a rental so we don't want to dump $$ into it like windows and insulation. 

IslandHopper --- 15 years ago -

The purpose of the big outdoor unit of your air-conditioner is to dissipate heat generated when freon is compressed.
So yes, it will work incrementally better if sunshine is not trying to ADD heat to it at the same time.
Now... whether or not it would make ENOUGH of a difference to be seen on your electric bill... probably not.

You'd get a MUCH better return on your money by putting up reflective blinds/curtains, or solar screens on the windows. 

Gigix4 --- 15 years ago -

Whatever you do, don't plant anything close to it. It needs good air circulation. 

Circlesmile --- 15 years ago -

A good a/c wil do a 25 degree split 97 degrees set 73. Most old a/c will only do 20 you have to listen for it to cycle and yes treat your windows. Tinting is the cheapest next is a piece of plywood painted white place squarely in window seal. 

RedMulch --- 15 years ago -

A good a/c wil do a 25 degree split 97 degrees set 73. Most old a/c will only do 20 you have to listen for it to cycle and yes treat your windows. Tinting is the cheapest next is a piece of plywood painted white place squarely in window seal.


How old is an "old air conditioner"? How long are they expected to last? 

tinman --- 15 years ago -

Actually...there is zero correlation between outside temp and leaving air temp. There are just too many variables. The shade factor mentioned here along with proper insulation and good tight windows and doors are key in good efficient air conditioning.

The way to see if your system is keeping up is to actually measure the entering and leaving air temps. Measure the air temp as it is entering your return air grill and then measure the temp as it is leaving a register.

There should be about 14-18 degree in the two temperatures. If there isn't, you might want to investigate why.

As for the shade on the condenser issue, it's debatable. The outdoor unit is actually there to condense the freon from a gaseous state to a liquid state. In the meantime the heat collected by the freon in your evaporator coil is dissipated through the top of your condenser. That heat you feel coming off of the top of the condenser is actually heat that has been removed from your house. I've seen condensers work incredibly well when sprayed with water while in operation. The air you get is incredibly cold. So it would stand to reason that shade over the unit couldn't hurt and might help. 

jjfingrainalready --- 15 years ago -


The way to see if your system is keeping up is to actually measure the entering and leaving air temps. Measure the air temp as it is entering your return air grill and then measure the temp as it is leaving a register.


Exactly. It's not the difference b/w the temp outside and the temp inside, it's these 2 temps that tell the story.

There should be about 14-18 degree in the two temperatures.

14 is pretty low. If you're return is 76 and you only have a 14* drop, that's blowing 62. I'd say something's not right, that's not very good. 18* minimum, possibly up to 25* depending on all the other variables mentioned. 

tinman --- 15 years ago -

Systems over 10 years old are just not going to get a drop across the coil more than 18 degrees. Now, your high efficiency 16 seer units that are buttoned up tighter than dick's hat band are going to get that.

Remember, a huge number of these houses in KW are still infested with that old grey flex duct that falls apart. If your flex is hot, so will your air be. 

Gigix4 --- 15 years ago -

I just finished taking down all of my vent covers and re-insulating and caulking between the vent and the sheetrock. I was amazed at the big gaps in some of them. It was a job but couldn't hurt. Some of the insulatuion up inside some looked pretty ragged. 

jjfingrainalready --- 15 years ago -

Systems over 10 years old are just not going to get a drop across the coil more than 18 degrees.

Our system is 10-11 years and we have a return of 76 and blowing about 52. I think that is excellent considering its age and the fact that the unit is unshaded on the west side of the house. However, it is not all original parts, the e-coil, piston, and a few other things have been replaced. Trying to get as much as we can out of it until we have the funds to get a new one. Last year, our A/C man discovered a rip in the return duct. No wonder I never felt truly comfortable! We had 18 feet of of duct work replaced. That, plus some extra insulation added over the winter has made a world of difference. We are comfortable with it set at 77*. 

BrianDTexan --- 15 years ago -

With the rash of AC Units being stolen, I am offering to build anyone who asks for it a cage for their AC Unit. Prices are reasonable and cages will be made to fit around your AC Unit, Not interrupt air flow and be bolted down to the pad below the unit. I will work with whoever your chosen contractor is, or sell direct. A Typical Cage for a 4 ton unit will run $325.00 including installation hardware. Installation is easy.... 4 holes drilled in concrete pad, bolts threaded in and if installation is desired, I can come tack weld the bolts in place for a small fee. Custom cages can be designed for an extra charge. Any cage ordered referencing KU will have 5% of the Sell price donated to Wounded Warriors. 