gma88 --- 15 years ago -

any recommendations for attic insulation? 

Scooter --- 15 years ago -

R-30 Batts , the blown in kind is kinda of messy . if you have a alot of wind going thru your attic the wind will blow it around . i suggest useing R-30 batts they stay in place .

ps. make sure you get the yellow kind of insulation . it doesn't itch as much as the pink insulation . 

gma88 --- 15 years ago -

any recommendations for someone to install? 

Gigix4 --- 15 years ago -

I'm thinking about adding insulation too just didn't know where to start or who to call.
I sure ain't getting up there and doing it myself - blowing it in OR laying batts. 

gma88 --- 15 years ago -

me either....had one quote but really high 

Gigix4 --- 15 years ago -

Who did you get the quote from gma88? Just wanted to know who NOT to call. :) 

G Keeng --- 15 years ago -

any recommendations for attic insulation?

You may find some pertinent information in the posts here. 

TeaLeaves --- 15 years ago -

I have attic fans that switch on at 120 degrees. Is that enough? 

gma88 --- 15 years ago -

G Keeng - thanks for the link...can you recommend a reliable company to look at the attic and install the insulation? We are new to the area. 

gma88 --- 15 years ago -

bump 

G Keeng --- 15 years ago -

I have attic fans that switch on at 120 degrees. Is that enough?

That depends on how much air it's removing, and - most importantly - if your attic has enough fresh air intake to supply what the fan is sucking out (usually in the form of soffit vents).

If you have fans that are just sucking out air willy-nilly, without regard to balanced intake - you are creating a negative pressure in your attic. This WILL ensure that your attic becomes much cooler.

Do you know why? Because it will be drawing nice cool air-conditioned (expensive) air right through the porous sheetrock of your ceiling.

The goal is to draw in the cooler air from the outside, not air condition your attic.

To determine if your fans are doing enough - and not too much, you first must determine the net free air flow requirements for your attic space. This is calculated using your square footage and a fixed ratio.

Next, you need to determine how much air is able to get into your attic through the soffit vents, and just how much air is being sucked out by your fans. This is measured in square inches for consistency.

Ideally you want a 60-40 balance. That is, 60% of the total NFA should be intake and 40% as exhaust. 50-50 is acceptable, but more exhaust than intake puts you in the negative pressure situation. This isn't that critical with passive exhaust like ridge-vents (properly applied), but is definitely a problem with active exhaust like powered fans.

And please tell me - since you have fans - that they aren't right next to ridge-vents or air-hawks! If they are - they aren't doing very much good if any at all. They would simply be sucking air right out from those vents and not from within your attic space.

One more thing....a properly ventilated attic (especially one with a radiant barrier applied to the underside of the roof decking) - shouldn't get more than about 20 degrees hotter than it is outside. That's about....120 degrees on a typically hot Houston Summer day. If you are letting your attic get hotter than this before "it" (the fans) kicks on and does something about it - it's too late. At least, it's too late to call that "efficient."

I am a big fan of (no pun intended) the solar powered fans. Properly applied, these things are the best. They simply run all day, as long as there's light - and HEAT. The better one's on the market are not that expensive, are made of very durable materials, run whisper quiet (they don't sound like a B-52 is landing on your roof everytime an electric one kicks on) and best of all....don't cost a dime to operate! Talk about efficient.

Powered fans - solar or otherwise - are not for every attic. There are certain circumstances that make them a poor or wrong choice for exhaust ventilation. So, please don't go out and slap a few on your roof and call it a day, or you may be solving one problem by creating a new one. 

jjfingrainalready --- 15 years ago -

we used:

Williams  

mc2imagescom --- 15 years ago -

we had ours blown in and our electric bill has more than paid for the expense. I will look for the number of the people we used 